How it works

What Héliomaison calculates, how, with which data, and what it cannot do. Everything is calculated from your description: address, outline of the house, windows and surroundings.

Using the tool

What is Héliomaison for?

To see how the sun lights each window of your house, existing or planned, through the day and the seasons: how many hours of sun on the glass, how much heat it lets in during summer (the overheating risk) and winter (the free gains), and if needed which overhang to fit to keep one without the other.

How do I describe my house?
  • Address: search for it or use “My location”. The map zooms in on it.
  • House: click each corner on the aerial photo, then the first point again. Each wall becomes a numbered façade (F1, F2…). Enter the wall height and the roof type.
  • Windows: click on a wall where the window is, then set its size, sill height, glazing and the floor area of the room behind it.
  • Surroundings: add trees and draw the neighbouring buildings that cast shade.
Where is my data stored?

Nowhere on a server: your whole description is written into the page address (after the #). Reloading the page keeps it; “Copy link” lets you share it or come back to it later (bookmark it). Opening the site without that link starts from scratch.

What does the “Sun shading” step do?

It sizes an overhang (a horizontal projection above the window) and side fins. The recommended depth is the smallest one that puts the whole pane in shade on the target summer date, over the chosen time range; the tool then checks how much sun it lets through on the winter date. The default summer date is the hot day (see “Hot summer outside”) when the sun is lowest, and therefore hardest to block. In the detailed analysis, a switch compares the results with and without shading.

Sun and shading

How is the sun's position calculated?

With standard astronomical formulas: solar declination by day of year (Spencer's formula) and the equation of time. Times shown are solar times (noon = sun at its highest); the matching clock time is shown alongside, based on the local time zone and daylight saving.

What do “hours of sun on the glass” mean?

The day is split into quarter-hours. At each step, the share of the pane in sun is measured on a grid of points, and only that share counts: a quarter-hour with half the pane in shade counts as 7.5 minutes. The figure is therefore an equivalent of the whole pane in sun.

It does not account for the sun's angle: an hour of low-angle sun counts as much as an hour of head-on sun. The energy actually received is in the gains, in kWh/m².

What shades a window?
  • The wall itself: the glass sits back in the wall (20 cm by default, adjustable per window). The sides and top of the opening block low-angle sun.
  • The other walls of the house: in an L- or U-shaped house, one wing can hide a window for part of the day.
  • The overhang and fins, once sized in the “Sun shading” step.
  • Neighbouring trees and buildings. Deciduous trees have no leaves from November to April (the reverse in the southern hemisphere) and then let the sun through.
  • Terrain: hills and mountains up to 12 km away, in 72 directions.
How are neighbouring trees and buildings taken into account?

Seen from the house, each one covers a sector of the horizon (its width) up to a certain height. Its full height is placed at its nearest point, which slightly overestimates the shade of a deep building. For a gable-roofed building, half the roof height is added to the wall height.

Energy and comfort

What are “solar gains” in kWh/m²?

The sun's heat that passes through the glass, per m² of glazing. It adds up direct sun (depending on shade and the angle at which it hits the glass), diffuse skylight and light reflected off the ground, then applies the glazing's solar factor (the share of heat it lets through). It is calculated hour by hour from real weather data.

GlazingSolar factor gU-value (W/m².K)
Double glazing0.61.3
Solar control double glazing0.351.3
Triple glazing0.50.8
How is room comfort simulated?

Hour by hour over five years of real weather, with a simplified thermal model based on the ISO 13790 standard: the room behind the window is a single volume that receives sun, loses heat through its walls and ventilation, and stores heat according to the thermal mass of the house.

  • Ceiling height 2.5 m; standard opaque walls (1.5 m² per m² of floor, well insulated); internal gains of 4 W/m².
  • Ventilation of 0.6 air changes per hour, 2 above 26 °C when it is cooler outside, 4 at night if “windows open at night” is ticked.
  • Heating so as not to drop below 19 °C; no air conditioning.
  • Thermal mass: light, medium, heavy.
Why so many hours above the overheating threshold?

Because the simulated room has no air conditioning, shutters or blinds closed during the day, and its walls are standard. The figure is a rough estimate for comparing windows or shading options, not a forecast of the actual temperature. That is why the verdicts rely on what the window itself brings in (see below). The threshold can be changed in “Advanced settings” (27 °C by default).

How do I read the “Winter” and “Summer” verdicts?
  • Winter: hours of sun on the glass at the winter solstice. Sunny from 6 h, some sun from 2 h, little sun below that.
  • Summer: heat let in from June to August. Low exposure below 110 kWh/m², moderate heat up to 150, highly exposed above.

These thresholds are calibrated on a climate like that of Lyon, France; elsewhere they are only indicative. The exact figures are in each window's details (⚙) and in the detailed analysis.

Data and sources

Where does the data come from?
  • Hourly weather: ERA5 reanalysis (Copernicus) via Open-Meteo, from 2020 to 2024: temperature, direct and diffuse radiation.
  • Local climate: daily maximum temperatures from 2005 to 2024, same source, averaged day by day.
  • Terrain: Open-Meteo elevations (about 90 m grid), read every 5° up to 12 km.
  • Addresses: the French national mapping agency (IGN) in France, OpenStreetMap (Nominatim) elsewhere.
  • Aerial imagery: IGN in France, Esri for the rest of the world.
What happens to my location and address?

“My location” uses your browser's geolocation, with your consent. The coordinates (rounded to the metre) are sent to the Héliomaison server only to find the nearest address, then the weather, climate and terrain for that place from the services listed above. An address typed into the search follows the same path. No account and no house description is kept on the server. To measure traffic, the site uses Vercel Web Analytics, with no cookies and no personal data: only the pages visited are counted, without the house description held in the link.

Limitations

What can't Héliomaison do?
  • The roof is not included in the shade the house casts on its own windows.
  • Shutters, blinds, curtains and how windows are actually used are not modelled.
  • Each room is simulated on its own, with standard walls: no real wall build-up and no heat exchange between rooms.
  • Terrain is coarse (90 m): a nearby bank or wall does not show up; draw it as a building.
  • Outside France, aerial imagery can be less sharp, and the verdict thresholds, calibrated on Lyon, are less representative.

It is a preliminary design tool for comparing options: have your project checked by an architect or a building energy consultant.

← Back to the simulator